To use this feature, on-site access to the device is required. Slide the switch on the front to the middle position and restart the CS141 by pulling the card out of the slot (press the reset button on the HW161) or briefly disconnect the power supply from the external device. After the restart, the device is in configuration mode and can only be reached at the IP 10.10.10.10/24.
Firmware version 2.14 - 2.22
Open a web browser, and type the following URL:
http(s)://10.10.10.10/resetPwd
user: admin
Password: cs141-snmp
Firmware version 2.24
On the login screen you will find the link “Forgot your Password”. Click on this link to start the password dialog.
You can then log in directly with the new password.
Note: The quick link via 10.10.10.10/resetPwd is not possible in this version!
Firmware version 2.26 and following versions
Open a web browser, and type the following URL:
http(s)://10.10.10.10/resetPwd
A dialogue box will appear and you are forced to enter a new password for the user admin.
Note: half-static web-based content!
Modern web browsers use techniques in which web-based content is stored in its own cache and reused when necessary - which affects the display and login speed of a web page. Display problems can also occur if the web browser does not update previously saved content or assigns it incorrectly. If you feel that the content is not displaying properly, clear the browser cache via Settings if necessary and press CTRL + F5 to rebuild the cache.
v.: 2025-07-23 FW 2.16-2.26